Thermo Scientific™ TraceGOLD™ GC Capillary Columns
Offering you a leap forward in GC capillary column performance delivering ultra low bleed, superior inertness and the highest levels of reproducibility guaranteed.
Product features:
Ultra low bleed – Leading to greater sensitivity, essential for GCMS applications, while providing extended column lifetime
High levels of reproducibility – Both run-to-run and column to column reproducibility. Expect every column to provide the same high levels of performance as the previous one
Superior inertness – Offering highly inert columns ensuring excellent peak shape and sensitivity, especially for highly active or difficult compounds
Wide range of stationary phases – Find a column suitable for your application
Filtered Search Results
Thermo Scientific™ TraceGOLD™ TG-624SilMS GC Columns, 1.4μm film thickness, 0.25mm I.D., 30m length
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Thermo Scientific™ TraceGOLD™ TG-624 and TG-624SilMS GC Columns
Optimize volatile organics analysis with this low-bleed, midpolarity GC column with high thermal stability.
Promotions are availablePolarity | Mid-Polar |
---|---|
USP Type | G43 |
Thermo Scientific™ TraceGOLD™ TG-WaxMS GC Columns
Analyze FAMEs with excellent thermal stability using this column.
Max. Temperature | 240/260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS |
Polarity | Polar |
USP Type | G14, G15, G16, G20, G39 |
Thermo Scientific™ TraceGOLD TG-5HT GC Columns
Thermo Scientific™ TraceGOLD TG-5HT GC Columns offer extended operation up to 400°C, ideal for high temperature GC applications.
Promotions are availableMax. Temperature | 380/400°C |
---|---|
Stationary Phase | TraceGOLD™ TG-5 HT |
Polarity | Low-Polar |
For Use With (Application) | Pesticides Analysis,GC/MS for Pesticides,GC/MS for Residual Solvents, Solvents, and Solvent Impurities |
USP Type | G27, G36 |
Product Line | TraceGOLD |
Thermo Scientific™ TraceGOLD™ TG-5MS GC Columns
Employ the most widely used MS phase in gas chromatography with the 5% phenyl phase Thermo Scientific™ TraceGOLD™ TG-5MS GC Column.
Promotions are availableStationary Phase | TraceGOLD™ TG-5 MS |
---|---|
USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD TG-1301MS GC Columns
Provides low-bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECDs and MS.
Max. Temperature | 260/280°C |
---|---|
Stationary Phase | TraceGOLD™ TG-1301 MS |
Polarity | Mid-Polar |
USP Type | G43 |
Thermo Scientific™ TraceGOLD™ TG-ALC Plus II GC Columns
Perform fast, full separation of blood alcohols and other volatile compounds by headspace gas chromatography using Thermo Scientific™ TraceGOLD™ TG-ALC GC columns.
Max. Temperature | 260°C |
---|---|
Product Line | TraceGOLD |
Thermo Scientific™ TraceGOLD™ TG-SQC GC Columns
Ensure the quality of your Thermo Scientific instrument when installed on site.
Diameter (Metric) Inner | 0.25 mm |
---|---|
Quantity | Each |
Film Thickness | 0.25 μm |
Product Line | TraceGOLD |
Functionality/Interaction Type | Benchmark Testing Only |
Thermo Scientific™ TraceGOLD TG-35MS AMINE GC Columns
Utilizes a chemically altered tubing surface to reduce peak tailing and eliminates the need for column priming when analysing amines and other basic compounds.
Max. Temperature | 220°C |
---|---|
Stationary Phase | TraceGOLD™ TG-35 MS Amine |
Polarity | Mid-Polar |
For Use With (Application) | GC/MS Amines Including Alkylamines, Diamines, Triamines and Ethanolamines,GC/MS for Nitrogen-Containing Heterocyclics |
Thermo Scientific™ TraceGOLD™ TG-WaxMS B GC Columns
Identify basic analytes with high performance, sensitivity, and reproducibility without derivatization or column priming.
Max. Temperature | 200/220°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS B |
Polarity | Polar |
Thermo Scientific™ TraceGOLD™ TG-WaxMT Metal GC Columns
Ensure excellent column-to-column reproducibility using the Thermo Scientific™ TraceGOLD™ TG-WaxMT GC Columns.
Max. Temperature | 260°C |
---|---|
Stationary Phase | TraceGOLD™ TG-WAXMS |
Polarity | Polar |
Temperature Range | 40°C°C to 260°C |
For Use With (Application) | GC for EPA Method 603 for Acrolein/Acrylonitrile,GC for Fatty Acid Methyl Esters (FAMEs), Flavor Compounds, Essential Oils, Amines, Solvents, and Xylene Isomers |
USP Type | G14, G15, G16, G20, G39 |
Thermo Scientific™ TraceGOLD TG-1MT Metal GC Columns
Push the limits of your analyses with these nonpolar, metal columns designed for elevated temperature use.
Max. Temperature | Up to 430°C |
---|---|
Polarity | Non-Polar |
Thermo Scientific™ TraceGOLD™ TG-1MS GC Columns
Choose the nonpolar Thermo Scientific™ TraceGOLD™ TG-1MS GC column for optimal signal-to-noise ratio, sensitivity, and MS integrity. Achieve consistent results with this low-bleed, stable column.
Polarity | Non-Polar |
---|
Thermo Scientific™ TraceGOLD™ TG-5MS Guard GC Columns with SafeGuard
Extend column lifetime and get more consistent results over a longer period of time.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MS |
Polarity | Low-Polar |
Temperature Range | -60°C to +330/350°C |
For Use With (Application) | Active Compounds Analysis,GC/MS for Analysis of Active Compounds |
USP Type | G27, G36 |
Thermo Scientific™ TraceGOLD™ TG-5MT Metal GC Columns
Give greater stability and inertness at elevated temperatures and when working with highly active compounds with Thermo Scientific™ TraceGOLD™ TG-5MT Metal GC Columns.
Max. Temperature | 330/350°C (Standard Columns), 430°C (Metal Columns) |
---|---|
Stationary Phase | TraceGOLD™ TG-5 MT |
Polarity | Low-Polar |
USP Type | G27, G36 |